Error Code 5°C LED LAMP
Defrosting heater stops too quickly before cycle completes
Moderate
Address soon - your appliance may not work properly
Also displayed as: 5°C indicator LED lamp
What This Means
Defrosting heater housing lost or in poor contact; Heater wire short circuit or broken; Temperature fuse in poor conditions; Heater power supply voltage too low; Defrosting relay malfunction
What actually causes this:
Heater power is insufficient due to low voltage or broken connection
First Thing to Check
Check if refrigerator is plugged into outlet with stable voltage; verify no brown discoloration on heater element
Parts Involved
How to Fix
- 1
1. Monitor defrost cycle duration after heater activation
- 2
2. If heating stops within 5 minutes, indicates low voltage condition
- 3
3. Measure resistance between heater terminals #1 and #3
- 4
4. Check heater voltage supply during defrost cycle
- 5
5. Verify thermal fuse resistance and continuity